メインコンテンツにスキップ
Moov logo

Moov Icon
AQUEOUS TECHNOLOGIES ZERO ION G3-18
    説明
    Ionic contamination, which comes from, among other sources, plating chemistries, flux activators, ionic surfactants, ethanolamines and perspiration, can lead to defects and failure conditions—most commonly in the form of corrosion and dendrite growth, which then lead to opens and shorts in the field. Densely populated assemblies and fine-pitch applications are especially prone to the effects of ionic contamination. The Zero Ion G3, a dynamic resistivity of solvent extract (ROSE) testing system, is a cost-effective and easy to use method of detecting ionic contamination on bare boards and printed circuit assemblies, allowing potential failures to be avoided.Process and Traceability DataIPC-001 and IPC TM650 recognize ROSE testing as an approved method of determining the cleanliness of circuit assemblies. Zero-Ion meets IPC's and other industrial cleanliness specification's including MIL-STD-2000A (in which the Zero Ion is specifically cited), MIL-P-28809, IPC-TM-650, and ANSI/J-STD-001B, IPC-TM650. Usable as a daily process monitoring tool, the Zero-Ion G3 can be operated by entry-level staff with minimal training. Zero-Ion G3's built-in SPC data recording captures all relevant testing data. Cleanliness results may be stored for later viewing, saved as a PDF on the hard drive or over a network, or sent to any Windows-compatible printer. The cleaning results database can be searched by date range, recipe name, board serial number and other details. Connect the Zero-Ion G3 to the company's network for remote viewing of SPC data. Additionally, real-time process information can be viewed during testing on the system's 18.5" LCD display.No-Clean (and All Other Flux Types) Capability Static-based cleanliness testers suffer from what's called the "saturation limit effect," making them less effective in evaluating assemblies that have been assembled with no-clean solder paste. Zero-Ion G3 uses dynamic filtering technology to ensure that all flux types can be tested. With Zero-Ion's dynamic filtering technology, test solution is filtered and re-deionized during the test, resulting in greater solubility/sensitivity that allows for enhanced detection of the weak ion activators commonly found in no-clean fluxes.Immersion Spray Action Eliminates Test InaccuraciesOpen-air spray systems can cause carbon dioxide adsorption, which leads to test inaccuracies. With the Zero-Ion, the assembly or bare board under test is submerged in test solution. Dozens of submerged jets then agitate the test solution, allowing all soluble contamination to be stripped off the assembly or bare board and measured. It is this immersion spraying action that gives the Zero Ion G3 system its superiority in ionic contamination detection.Ambient Testing for Cost-Effective OperationBecause the Zero-Ion G3, unlike many other systems, is able to perform all tests at ambient test solution temperature, no test solution heater is needed. This provides a savings on several fronts: reduced power consumption, reduced machine startup times, and reduced test solution evaporation. It also eliminates safety concerns associated with heaters.
    構成
    Cleanliness Measurement Standard Resistivity of solvent extract (ROSE) test Other Cleanliness Standards Met: MIL-P-28809, IPC-TM-650 Test Duration: From 30 seconds to 4 minutes, depending on contamination Test Solution: 75% IPA / 25% DI Measurement Technology: Test board immersion, dynamic testing Maximum Test Board Size: 12" x 12" (304 mm x 304 mm) standard (specify when ordering): 18" x 18" (457 mm x 457 mm) - this is for G3-18 model 24" x 24" (609 x 609 mm) Maximum Test Board Height: 3.5" (89 mm) Control System: All-in-One PC with 18.5" LCD interface ESD Counter Top: Standard Auto Print & SPC Data Storage: Standard Dynamic Filtration: Standard Power Requirements: 120 VAC 10 amps or 240 VAC 5 amps Dimensions (WxLxH): 39" x 35" x 37" (99 x 635 x 940 mm) (Not including countertop, monitor & keyboard holder) Weight: 288 lbs (131 kg)
    OEMモデルの説明
    提供なし
    ドキュメント
    verified-listing-icon

    検証済み

    カテゴリ
    Aqueous / Ultrasonic / Megasonic Cleaner

    最終検証: 5日前

    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    139703


    ウェーハサイズ:

    不明


    ヴィンテージ:

    不明


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    同様のリスト
    すべて表示
    AQUEOUS TECHNOLOGIES ZERO ION G3-18

    AQUEOUS TECHNOLOGIES

    ZERO ION G3-18

    Aqueous / Ultrasonic / Megasonic Cleaner
    ヴィンテージ: 0状態: 中古
    最終確認5日前

    AQUEOUS TECHNOLOGIES

    ZERO ION G3-18

    verified-listing-icon
    検証済み
    カテゴリ
    Aqueous / Ultrasonic / Megasonic Cleaner
    最終検証: 5日前
    listing-photo-3eae253bb559476788229e38a0277819-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    139703


    ウェーハサイズ:

    不明


    ヴィンテージ:

    不明


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    説明
    Ionic contamination, which comes from, among other sources, plating chemistries, flux activators, ionic surfactants, ethanolamines and perspiration, can lead to defects and failure conditions—most commonly in the form of corrosion and dendrite growth, which then lead to opens and shorts in the field. Densely populated assemblies and fine-pitch applications are especially prone to the effects of ionic contamination. The Zero Ion G3, a dynamic resistivity of solvent extract (ROSE) testing system, is a cost-effective and easy to use method of detecting ionic contamination on bare boards and printed circuit assemblies, allowing potential failures to be avoided.Process and Traceability DataIPC-001 and IPC TM650 recognize ROSE testing as an approved method of determining the cleanliness of circuit assemblies. Zero-Ion meets IPC's and other industrial cleanliness specification's including MIL-STD-2000A (in which the Zero Ion is specifically cited), MIL-P-28809, IPC-TM-650, and ANSI/J-STD-001B, IPC-TM650. Usable as a daily process monitoring tool, the Zero-Ion G3 can be operated by entry-level staff with minimal training. Zero-Ion G3's built-in SPC data recording captures all relevant testing data. Cleanliness results may be stored for later viewing, saved as a PDF on the hard drive or over a network, or sent to any Windows-compatible printer. The cleaning results database can be searched by date range, recipe name, board serial number and other details. Connect the Zero-Ion G3 to the company's network for remote viewing of SPC data. Additionally, real-time process information can be viewed during testing on the system's 18.5" LCD display.No-Clean (and All Other Flux Types) Capability Static-based cleanliness testers suffer from what's called the "saturation limit effect," making them less effective in evaluating assemblies that have been assembled with no-clean solder paste. Zero-Ion G3 uses dynamic filtering technology to ensure that all flux types can be tested. With Zero-Ion's dynamic filtering technology, test solution is filtered and re-deionized during the test, resulting in greater solubility/sensitivity that allows for enhanced detection of the weak ion activators commonly found in no-clean fluxes.Immersion Spray Action Eliminates Test InaccuraciesOpen-air spray systems can cause carbon dioxide adsorption, which leads to test inaccuracies. With the Zero-Ion, the assembly or bare board under test is submerged in test solution. Dozens of submerged jets then agitate the test solution, allowing all soluble contamination to be stripped off the assembly or bare board and measured. It is this immersion spraying action that gives the Zero Ion G3 system its superiority in ionic contamination detection.Ambient Testing for Cost-Effective OperationBecause the Zero-Ion G3, unlike many other systems, is able to perform all tests at ambient test solution temperature, no test solution heater is needed. This provides a savings on several fronts: reduced power consumption, reduced machine startup times, and reduced test solution evaporation. It also eliminates safety concerns associated with heaters.
    構成
    Cleanliness Measurement Standard Resistivity of solvent extract (ROSE) test Other Cleanliness Standards Met: MIL-P-28809, IPC-TM-650 Test Duration: From 30 seconds to 4 minutes, depending on contamination Test Solution: 75% IPA / 25% DI Measurement Technology: Test board immersion, dynamic testing Maximum Test Board Size: 12" x 12" (304 mm x 304 mm) standard (specify when ordering): 18" x 18" (457 mm x 457 mm) - this is for G3-18 model 24" x 24" (609 x 609 mm) Maximum Test Board Height: 3.5" (89 mm) Control System: All-in-One PC with 18.5" LCD interface ESD Counter Top: Standard Auto Print & SPC Data Storage: Standard Dynamic Filtration: Standard Power Requirements: 120 VAC 10 amps or 240 VAC 5 amps Dimensions (WxLxH): 39" x 35" x 37" (99 x 635 x 940 mm) (Not including countertop, monitor & keyboard holder) Weight: 288 lbs (131 kg)
    OEMモデルの説明
    提供なし
    ドキュメント
    同様のリスト
    すべて表示
    AQUEOUS TECHNOLOGIES ZERO ION G3-18

    AQUEOUS TECHNOLOGIES

    ZERO ION G3-18

    Aqueous / Ultrasonic / Megasonic Cleanerヴィンテージ: 0状態: 中古最終検証:5日前
    AQUEOUS TECHNOLOGIES ZERO ION G3-18

    AQUEOUS TECHNOLOGIES

    ZERO ION G3-18

    Aqueous / Ultrasonic / Megasonic Cleanerヴィンテージ: 0状態: 中古最終検証:60日以上前
    AQUEOUS TECHNOLOGIES ZERO ION G3-18

    AQUEOUS TECHNOLOGIES

    ZERO ION G3-18

    Aqueous / Ultrasonic / Megasonic Cleanerヴィンテージ: 0状態: 中古最終検証:60日以上前