説明
RF IMPEDANCE / MATERIAL ANALYZER構成
4291B (Test Head and Test Station) 1.8-m Error-Free cableOEMモデルの説明
The HP 4291B RF impedance/material analyzer provides a total solution for high-accuracy and easy measurement of surface-mount components and dielectric/magnetic materials. The HP 4291B uses a direct current voltage measurement technique, opposing the reflection measurement technique, for more accurate impedance measurement over wide impedance range.Basic impedance accuracy is ± 0.8 % . High Q accuracy enables low-loss component analysis. An internal synthesizer sweeps frequency from 1 MHz to 1.8 G Hz with 1 mHz resolution. A 1.8 -m error-less cable connects the analyzer to a test station so you can ex tend your test point away from the analyzer without losing accuracy. Advanced calibration and error compensation function eliminate measurement error factors in fixtures and assure high accuracy and repeatability at DUT/MUT.ドキュメント
ドキュメントなし
KEYSIGHT / AGILENT / HEWLETT-PACKARD (HP)
4291B
検証済み
カテゴリ
Electronic Test
最終検証: 60日以上前
主なアイテムの詳細
状態:
Used
稼働ステータス:
不明
製品ID:
80113
ウェーハサイズ:
不明
ヴィンテージ:
不明
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
KEYSIGHT / AGILENT / HEWLETT-PACKARD (HP)
4291B
カテゴリ
Electronic Test
最終検証: 60日以上前
主なアイテムの詳細
状態:
Used
稼働ステータス:
不明
製品ID:
80113
ウェーハサイズ:
不明
ヴィンテージ:
不明
Have Additional Questions?
Logistics Support
Available
Money Back Guarantee
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
説明
RF IMPEDANCE / MATERIAL ANALYZER構成
4291B (Test Head and Test Station) 1.8-m Error-Free cableOEMモデルの説明
The HP 4291B RF impedance/material analyzer provides a total solution for high-accuracy and easy measurement of surface-mount components and dielectric/magnetic materials. The HP 4291B uses a direct current voltage measurement technique, opposing the reflection measurement technique, for more accurate impedance measurement over wide impedance range.Basic impedance accuracy is ± 0.8 % . High Q accuracy enables low-loss component analysis. An internal synthesizer sweeps frequency from 1 MHz to 1.8 G Hz with 1 mHz resolution. A 1.8 -m error-less cable connects the analyzer to a test station so you can ex tend your test point away from the analyzer without losing accuracy. Advanced calibration and error compensation function eliminate measurement error factors in fixtures and assure high accuracy and repeatability at DUT/MUT.ドキュメント
ドキュメントなし