
説明
説明なし構成
Mask Aligner Karl SUSS MicroTec MA6 - UV lithography system Equipment: UV exposure at 365 nm, Backlight unit with NIR camera, Wafer chucks (transmitted light), mask holder, Accessories: LCPLAN FL 20x/0.40 lens, LMPLFLN 20x/0.40 lens, 11.25x0.16 lens (separation), Optometer without sensor with case, Mask holder MA6/BA6/BL/Cont/M-3, Mask holder MA6/BA6/BL/Prox/Cont, Sola-Check accessories, Chuck MA6/BA6/VAC/TEFFLON/W-100/S.OEMモデルの説明
The MA6 has upgraded optics designed to output in the mid-UV (250nm) range. The lamp is controlled by a CIC 100 constant intensity controller capable of delivering user-selectable UV doses which remain stable during the life of the lamp. Optical sensors monitor the UV output dose and provide feedback to the controller. There are 2 selectable channels. Both channels operate the lamp near its “idle power” (475W) to maximize lamp life. Because the lamp operates in constant intensity mode, the actual power will vary over time as the lamp ages.ドキュメント
ドキュメントなし
カテゴリ
Mask/Bond Aligners
最終検証: 60日以上前
主なアイテムの詳細
状態:
Used
稼働ステータス:
Deinstalled / Palletized
製品ID:
128496
ウェーハサイズ:
不明
ヴィンテージ:
2001
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
同様のリスト
すべて表示SUSS MicroTec / KARL SUSS
MA6
カテゴリ
Mask/Bond Aligners
最終検証: 60日以上前
主なアイテムの詳細
状態:
Used
稼働ステータス:
Deinstalled / Palletized
製品ID:
128496
ウェーハサイズ:
不明
ヴィンテージ:
2001
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
説明
説明なし構成
Mask Aligner Karl SUSS MicroTec MA6 - UV lithography system Equipment: UV exposure at 365 nm, Backlight unit with NIR camera, Wafer chucks (transmitted light), mask holder, Accessories: LCPLAN FL 20x/0.40 lens, LMPLFLN 20x/0.40 lens, 11.25x0.16 lens (separation), Optometer without sensor with case, Mask holder MA6/BA6/BL/Cont/M-3, Mask holder MA6/BA6/BL/Prox/Cont, Sola-Check accessories, Chuck MA6/BA6/VAC/TEFFLON/W-100/S.OEMモデルの説明
The MA6 has upgraded optics designed to output in the mid-UV (250nm) range. The lamp is controlled by a CIC 100 constant intensity controller capable of delivering user-selectable UV doses which remain stable during the life of the lamp. Optical sensors monitor the UV output dose and provide feedback to the controller. There are 2 selectable channels. Both channels operate the lamp near its “idle power” (475W) to maximize lamp life. Because the lamp operates in constant intensity mode, the actual power will vary over time as the lamp ages.ドキュメント
ドキュメントなし