    The Thermo Scientific NanoDrop 8000 Microvolume UV-Vis Spectrophotometer provides quick, easy nucleic acid and protein quantification. Perfect for higher throughput workflows, the NanoDrop 8000 instrument can measure multiple samples simultaneously using only 1- 2 μL of sample. Using an 8-channel pipette to dispense samples on a linear array of pedestals, you can easily measure 96 samples in less than six minutes. Features: - Designed for micro-volume (1μL) samples - No dilutions required, even for high concentration samples - Direct, easy measurements from tubes or 96-well plates - Can measure multiple samples in one measurement cycle, up to eight samples at one time - Single sample mode - Preconfigured methods for common applications such as Nucleic Acid, Protein A280, Microarray, Protein and Labels, Pierce 660, Bradford, BCA, Lowry and more - User-friendly software for creating custom methods and options to design reports and export data - Patented sample retention system eliminates the need for cuvets - Full spectrum (220 to 750nm) - Calculates sample purity ratios (260/280)
    構成
    Specifications: Absorbance Accuracy: 3% (at 0.74 Abs at 350nm) Detector Type: 2048-element linear silicon CCD array Wavelength Accuracy: ±1 nm Absorbance Range: 0 - 75Abs Accuracy: 0.003 *SD of 10 individual measurements at 0.74Abs Accuracy (Absorption): 3% (at .74 at 350nm) Applications: Nucleic acid, protein, cell culture and custom methods Compatibility: Professional versions of Microsoft™ Windows™ 7 (32 bit and 64 bit), Windows Vista (32 bit), and Windows XP (32 bit). Connections: USB Detection Limits: 2.5 ng/µL (dsDNA), 0.15 mg/mL (BSA) Detection Range: 2.5-3,700 ng/µL (dsDNA), 0.15 - 100 mg/mL (BSA) Footprint: 9.45" x 12.6" (24 x 32 cm) Lamp: Xenon Flash Lamp Measurement Time : <20 sec. No. of Samples: Up to 8 Pathlength (Metric): 0.2 and 1.0 mm Power: 12VDC Sample Volume: 1µL Spectral Resolution: ≤3 nm (FWHM at Hg 546.1 nm) Wattage: ±1 nm Wavelength Range: 220 - 750 nm Weight: 7.5 lbs. (3.4 kg.)
    OEMモデルの説明
    Spectrophotometer
    ドキュメント

    ドキュメントなし

    THERMOFISHER SCIENTIFIC

    NANODROP 8000

    verified-listing-icon

    検証済み

    カテゴリ
    Spectrometer / SIMS

    最終検証: 60日以上前

    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    78771


    ウェーハサイズ:

    不明


    ヴィンテージ:

    不明


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    同様のリスト
    すべて表示
    THERMOFISHER SCIENTIFIC NANODROP 8000

    THERMOFISHER SCIENTIFIC

    NANODROP 8000

    Spectrometer / SIMS
    ヴィンテージ: 0状態: 中古
    最終確認60日以上前

    THERMOFISHER SCIENTIFIC

    NANODROP 8000

    verified-listing-icon
    検証済み
    カテゴリ
    Spectrometer / SIMS
    最終検証: 60日以上前
    listing-photo-7f62fd4638ae4037a304581229260b90-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    78771


    ウェーハサイズ:

    不明


    ヴィンテージ:

    不明


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    説明
    The Thermo Scientific NanoDrop 8000 Microvolume UV-Vis Spectrophotometer provides quick, easy nucleic acid and protein quantification. Perfect for higher throughput workflows, the NanoDrop 8000 instrument can measure multiple samples simultaneously using only 1- 2 μL of sample. Using an 8-channel pipette to dispense samples on a linear array of pedestals, you can easily measure 96 samples in less than six minutes. Features: - Designed for micro-volume (1μL) samples - No dilutions required, even for high concentration samples - Direct, easy measurements from tubes or 96-well plates - Can measure multiple samples in one measurement cycle, up to eight samples at one time - Single sample mode - Preconfigured methods for common applications such as Nucleic Acid, Protein A280, Microarray, Protein and Labels, Pierce 660, Bradford, BCA, Lowry and more - User-friendly software for creating custom methods and options to design reports and export data - Patented sample retention system eliminates the need for cuvets - Full spectrum (220 to 750nm) - Calculates sample purity ratios (260/280)
    構成
    Specifications: Absorbance Accuracy: 3% (at 0.74 Abs at 350nm) Detector Type: 2048-element linear silicon CCD array Wavelength Accuracy: ±1 nm Absorbance Range: 0 - 75Abs Accuracy: 0.003 *SD of 10 individual measurements at 0.74Abs Accuracy (Absorption): 3% (at .74 at 350nm) Applications: Nucleic acid, protein, cell culture and custom methods Compatibility: Professional versions of Microsoft™ Windows™ 7 (32 bit and 64 bit), Windows Vista (32 bit), and Windows XP (32 bit). Connections: USB Detection Limits: 2.5 ng/µL (dsDNA), 0.15 mg/mL (BSA) Detection Range: 2.5-3,700 ng/µL (dsDNA), 0.15 - 100 mg/mL (BSA) Footprint: 9.45" x 12.6" (24 x 32 cm) Lamp: Xenon Flash Lamp Measurement Time : <20 sec. No. of Samples: Up to 8 Pathlength (Metric): 0.2 and 1.0 mm Power: 12VDC Sample Volume: 1µL Spectral Resolution: ≤3 nm (FWHM at Hg 546.1 nm) Wattage: ±1 nm Wavelength Range: 220 - 750 nm Weight: 7.5 lbs. (3.4 kg.)
    OEMモデルの説明
    Spectrophotometer
    ドキュメント

    ドキュメントなし

    同様のリスト
    すべて表示
    THERMOFISHER SCIENTIFIC NANODROP 8000

    THERMOFISHER SCIENTIFIC

    NANODROP 8000

    Spectrometer / SIMSヴィンテージ: 0状態: 中古最終検証:60日以上前