メインコンテンツにスキップ
Moov logo

Moov Icon
TEL / TOKYO ELECTRON TELINDY PLUS
    説明
    Diffusion Tool
    構成
    ONO configuration System variant: B Furnace cabinet, heater chamber, load port and wafer load automation Special vacuum piping and exhaust box Gas box cabinet, gas detector box and power box System: Safety specification: SEMI S2-0706 Heater: Mid-Temp. VMM-56-002 / 5 zones / 500-1000°C Process condition: AP Maximum operating temperature: 800-1050°C ART control: None N2 load lock: Yes Wafer type: Si / SEMI STD-Notch Production wafer capacity: 100 Boat operation (handling position): Single boat type (B/E) WAVES software: Ver 8.04R000 Seismic isolation configuration: None Furnace: Dewpoint meter for N2 load lock: None Ionizer: Ion System / 421 Chemical pre-filter for acid: Yes Chemical pre-filter for alkali: None Chemical pre-filter for hydrocarbon: Yes Side maintenance: None O2 density control for N2 load lock: Yes N2 boat shower wafer cooling: Yes Furnace temperature controller: Model560A Carrier type: FOUP / 25 slots SEMI STD FOUP: Entegris / A300 Carrier stage capacity: 18 Info pads A/B and C/D: Pin Fork material: Al2O3 + PEEK W/T type: 1+4 edge grip W/T auto teaching: Yes Furnace exhaust: Top connection Cooling water: Bottom connection Gas system: IGS type: IGS 1.125" W-seal rail-mount IGS maker: CKD Tubing bends: Less than 90° IGS final filter: Entegris IGS regulator: CKD IGS MFC: HORIBA STEC / Digital IGS pressure transducer: Nagano Liquid source vapor system: Schumacher / Vapor Guard Auto-refill system: Schumacher / CG2000 Ozone delivery system: None External torch unit: Low flow torch with dilution PAC: None Incoming gas, gas vent, gas unit exhaust and process gas exhaust: Bottom connections Exhaust: Exhaust pressure control for AP process: Differential pressure control AP process exhaust pressure controller: Brooks / 12146G01 Condenser: Yes Reactor: Liner tube (AP): CVD-coated SiC Process tube (AP, AP+Sub-AP): Quartz single Inner T/C: SiC liner tube inscribed type (for HT/MT heater) Tube sealing: N2 purge + O-ring Boat: 119-slot SiC boat Boat rotation: Yes Pedestal: Quartz + SiC Turntable: Inconel Cap heater: None Auto shutter: No shutter purge type Earthquake countermeasure: Yes Reactor O-ring: Viton Power: Three-phase voltage: 480 VAC Three-phase connection: Star Single-phase voltage: 120 VAC Single-phase connection: Grounded Frequency: 60 Hz Wattmeter: None Power cable input entrance: Power box top FNC to power box cable length: 30 m Power box to refill system cable length: 30 m Interface: Host communications: Comply with GJG Equipment host interface: Gas box top HSMS (10Base-T/100Base-TX) Ingenio: Yes OHT capability: Yes AGV / RGV / PGV capability: None Load port operation: Upper PIO interface location: FNC top PIO: Hokuyo / DMS-HB1-Z Carrier ID reader/writer type: RF CIDRW lower and upper load ports: Read CIDRW FIMS: Write CIDRW: Omron / V640-HS61 CIDRW tag orientation: Horizontal EEC (Equipment Engineering Capability): None Signal tower: LCE-402 / FBW Signal tower colors from top: Red / Yellow / Green / Blue Signal tower location: Front Front operation panel: Yes MMI and gas flowchart: Gas box and front operation panel installed Cabinet exhaust pressure display unit: Pa
    OEMモデルの説明
    TELINDY PLUS™ is a cutting-edge thermal processing technology that combines the best features of the TELFORMULA™ minibatch system and the previous generation TELINDY™ platform. It offers improved process performance and productivity, with new enhancements such as improved maintenance access, dry gas chamber cleaning, and low O2 environment loading area control. These features contribute to yield increases by managing small particles more effectively. The highest levels of productivity are achieved by combining a 125 wafer load size with TEL’s FTPS™ responsive heater and a dual boat system option. TELINDY PLUS™ can be used for a wide range of applications, from traditional silicon treatments to leading edge ALD processes and radical oxidation. It represents the convergence of demonstrated experience and advanced technology, making it a powerful tool for thermal processing.
    ドキュメント

    ドキュメントなし

    verified-listing-icon

    検証済み

    カテゴリ
    Furnaces / Diffusion

    最終検証: 24日前

    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    154694


    ウェーハサイズ:

    12"/300mm


    ヴィンテージ:

    不明


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    同様のリスト
    すべて表示
    TEL / TOKYO ELECTRON TELINDY PLUS

    TEL / TOKYO ELECTRON

    TELINDY PLUS

    Furnaces / Diffusion
    ヴィンテージ: 2014状態: 中古
    最終確認3日前

    TEL / TOKYO ELECTRON

    TELINDY PLUS

    verified-listing-icon
    検証済み
    カテゴリ
    Furnaces / Diffusion
    最終検証: 24日前
    listing-photo-c6846a020368483d9a6cde711303f16e-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    主なアイテムの詳細

    状態:

    Used


    稼働ステータス:

    不明


    製品ID:

    154694


    ウェーハサイズ:

    12"/300mm


    ヴィンテージ:

    不明


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    説明
    Diffusion Tool
    構成
    ONO configuration System variant: B Furnace cabinet, heater chamber, load port and wafer load automation Special vacuum piping and exhaust box Gas box cabinet, gas detector box and power box System: Safety specification: SEMI S2-0706 Heater: Mid-Temp. VMM-56-002 / 5 zones / 500-1000°C Process condition: AP Maximum operating temperature: 800-1050°C ART control: None N2 load lock: Yes Wafer type: Si / SEMI STD-Notch Production wafer capacity: 100 Boat operation (handling position): Single boat type (B/E) WAVES software: Ver 8.04R000 Seismic isolation configuration: None Furnace: Dewpoint meter for N2 load lock: None Ionizer: Ion System / 421 Chemical pre-filter for acid: Yes Chemical pre-filter for alkali: None Chemical pre-filter for hydrocarbon: Yes Side maintenance: None O2 density control for N2 load lock: Yes N2 boat shower wafer cooling: Yes Furnace temperature controller: Model560A Carrier type: FOUP / 25 slots SEMI STD FOUP: Entegris / A300 Carrier stage capacity: 18 Info pads A/B and C/D: Pin Fork material: Al2O3 + PEEK W/T type: 1+4 edge grip W/T auto teaching: Yes Furnace exhaust: Top connection Cooling water: Bottom connection Gas system: IGS type: IGS 1.125" W-seal rail-mount IGS maker: CKD Tubing bends: Less than 90° IGS final filter: Entegris IGS regulator: CKD IGS MFC: HORIBA STEC / Digital IGS pressure transducer: Nagano Liquid source vapor system: Schumacher / Vapor Guard Auto-refill system: Schumacher / CG2000 Ozone delivery system: None External torch unit: Low flow torch with dilution PAC: None Incoming gas, gas vent, gas unit exhaust and process gas exhaust: Bottom connections Exhaust: Exhaust pressure control for AP process: Differential pressure control AP process exhaust pressure controller: Brooks / 12146G01 Condenser: Yes Reactor: Liner tube (AP): CVD-coated SiC Process tube (AP, AP+Sub-AP): Quartz single Inner T/C: SiC liner tube inscribed type (for HT/MT heater) Tube sealing: N2 purge + O-ring Boat: 119-slot SiC boat Boat rotation: Yes Pedestal: Quartz + SiC Turntable: Inconel Cap heater: None Auto shutter: No shutter purge type Earthquake countermeasure: Yes Reactor O-ring: Viton Power: Three-phase voltage: 480 VAC Three-phase connection: Star Single-phase voltage: 120 VAC Single-phase connection: Grounded Frequency: 60 Hz Wattmeter: None Power cable input entrance: Power box top FNC to power box cable length: 30 m Power box to refill system cable length: 30 m Interface: Host communications: Comply with GJG Equipment host interface: Gas box top HSMS (10Base-T/100Base-TX) Ingenio: Yes OHT capability: Yes AGV / RGV / PGV capability: None Load port operation: Upper PIO interface location: FNC top PIO: Hokuyo / DMS-HB1-Z Carrier ID reader/writer type: RF CIDRW lower and upper load ports: Read CIDRW FIMS: Write CIDRW: Omron / V640-HS61 CIDRW tag orientation: Horizontal EEC (Equipment Engineering Capability): None Signal tower: LCE-402 / FBW Signal tower colors from top: Red / Yellow / Green / Blue Signal tower location: Front Front operation panel: Yes MMI and gas flowchart: Gas box and front operation panel installed Cabinet exhaust pressure display unit: Pa
    OEMモデルの説明
    TELINDY PLUS™ is a cutting-edge thermal processing technology that combines the best features of the TELFORMULA™ minibatch system and the previous generation TELINDY™ platform. It offers improved process performance and productivity, with new enhancements such as improved maintenance access, dry gas chamber cleaning, and low O2 environment loading area control. These features contribute to yield increases by managing small particles more effectively. The highest levels of productivity are achieved by combining a 125 wafer load size with TEL’s FTPS™ responsive heater and a dual boat system option. TELINDY PLUS™ can be used for a wide range of applications, from traditional silicon treatments to leading edge ALD processes and radical oxidation. It represents the convergence of demonstrated experience and advanced technology, making it a powerful tool for thermal processing.
    ドキュメント

    ドキュメントなし

    同様のリスト
    すべて表示
    TEL / TOKYO ELECTRON TELINDY PLUS

    TEL / TOKYO ELECTRON

    TELINDY PLUS

    Furnaces / Diffusionヴィンテージ: 2014状態: 中古最終検証:3日前
    TEL / TOKYO ELECTRON TELINDY PLUS

    TEL / TOKYO ELECTRON

    TELINDY PLUS

    Furnaces / Diffusionヴィンテージ: 2014状態: 中古最終検証:3日前
    TEL / TOKYO ELECTRON TELINDY PLUS

    TEL / TOKYO ELECTRON

    TELINDY PLUS

    Furnaces / Diffusionヴィンテージ: 2012状態: 中古最終検証:30日以上前